Sign In | Join Free | My bushorchimp.com
China Hangzhou Union Industrial Gas-Equipment Co., Ltd. logo
Hangzhou Union Industrial Gas-Equipment Co., Ltd.
Hangzhou Union Industrial Gas-Equipment Co., Ltd. Premium Quality low pressure Air separation
Active Member

11 Years

Home > Oxygen Gas Plant >

Air Separation Oxygen Gas Plant , 380v 50hz High Purity Liquid Nitrogen Generator

Hangzhou Union Industrial Gas-Equipment Co., Ltd.

Air Separation Oxygen Gas Plant , 380v 50hz High Purity Liquid Nitrogen Generator

Place of Origin : Zhejiang ,China ( mainland)

Brand Name : UIG

Certification : ISO 9001:2000

Model Number : KDO, KDON

MOQ : 1 SET

Price : Negotiation

Packaging Details : Sea Worthy Packing

Delivery Time : 120 Days

Payment Terms : T/T ,L/C

Supply Ability : 2-3 Sets Per Month

O2 flow : 50,60,80,100m³/h

O2 pressure : 15 -25MPA

O2 purity : ≥99.7%

Operating pressur : 1.2Mpa

Power : 76-1000 KW

Product name : Cryogenic Oxygen Plant

Production capacity : 50-1000 m3/hour

Voltage : 380v,220V 50HZ

Contact Now

Air Separation Oxygen Gas Plant , 380v 50hz High Purity Liquid Nitrogen Generator

Quick Details:

Condition:new
Place of origin:China(mainland)
Brand name:UIG
Model number:KDO, KDON SERIES
Production capacity:50-1000 m3/hour
Power :76-1000 KW
Voltage:380v,220V 50HZ
Certification:ISO 9001:2000
Warranty:1 year
Life:20 years with proper maintenance
After-sales service provided: Engineers available to service plants overseas
Usage: medical (oxygen, liquid oxygen,nitrogen,liquid nitrogen)
UIG Air separation plants are designed for a vast range of capacities and products summarized below: FOR OXYGEN 99.7 % AND NITROGEN 99.999%



Specifications:

Model contents

KZO-50

KZO-60

KZO-80

KZO-100

O2 flow

50 m³/h

60 m³/h

80 m³/h

100 m³/h

O2 purity

≥99.7%

≥99.7%

≥99.7%

≥99.7%

O2 pressure

15 -25MPA

15 -25MPA

15 -25MPA

15 -25MPA

Operating pressure

1.2Mpa

1.2Mpa

1.2Mpa

1.2Mpa

Start-up time

8-12 Hours

8-12 Hours

8-12 Hours

8-12 Hours

Operating period

≥1 Years

≥1 Years

≥1 Years

≥1 Years

Model contents

KDON-
180-20

KDON-
300-50

KDON-
350-80

KDON-
500-150

KDON-
800-200

KDON-
1000-300

Gox flow

Nm³/h

180

300

350

500

800

100

Gox purity

%(O2)

≥99.7

≥99.7

≥99.7

≥99.7

≥99.7

≥99.7

Gan flow

Nm³/h

20

50

80

150

200

300

Gan purity

Ppm(O2)

≤10

≤10

≤10

≤10

≤10

≤10

Operating pressure

Mpa

1

1

1

1

1

1

Start-up time

hour

≤10

≤10

≤8

≤8

≤8

≤8

Operating period

year

≥1

≥1

≥1

≥2

≥2

≥2

Oxygen filling (or booster) with liquid pump.



Description:



The Plant uses normal temperature molecular sieve adsorption, medium pressure booster expansion reflux flow.
Raw air is sucked from the atmosphere,It is going through filter for removal of dust and mechanical impurities.,then it is compressed to a certain degree by single stage screw compressor,via end stage cooler, air pre-cooling system, the air is cooled to approx. 8℃. After water separation moisture is separated in water separator and then it goes to purifier for removal of moisture, CO2, C2H2 and hydrogen dioxide.
Then most part of air enters main heat exchanger to be cooled to saturated tempt. and partly is liquefied to the lower part of lower column; another part of air is compressed to a certain degree through two stage compression booster, via end stage cooler enters into oxygen heat exchanger to be cooled to be near saturated temperature, then after throttle goes to lower column. Through lower column pre-distillation we can get enriched oxygen liquid air from the bottom of the column. After cooling through sub-cooler,after throttled it goes to the middle part of upper column as reflux liquid for rectification. WN is obtained from the top of lower column, after condensed through condenser-evaporator, a part of WN is used as rectification reflux liquid for lower column; another part after cooling through sub-cooler and after throttling goes to the top of upper column as rectification reflux liquid. Pure liquid oxygen is obtained from the bottom of upper column, and it is condensed by condenser-evaporator. Liquid oxygen is abstracted from the bottom after cooling through sub-cooler, then it goes to LOX pump to be pressurized. It is evaporated in O2 heat exchanger and is reheated to normal tempt and then directly goes to oxygen filling ramp for filling of cylinders.
WN from the top of upper column goes through sub-cooler, the ower part of main heat exchanger to be reheated to a certain tempt. Then it goes to expansion turbine to create cold and returns to sub-cooler and main heat exchanger again to be reheated to normal tempt. A part of it passes to purifier as regenerating gas resource and another part goes to be vented partly.



Applications:



we supplied to many countries (Russia, Kazakhstan, Tajikistan, India, Bangladesh, Thailand, Philippines, North Korea, Mongolia, Equatorial Guinea, Botswana, Zambia, Angola, Tanzania) .



Competitive Advantage:

1. It adopts up-to-date air separation technics flow and reasonable equipment schemes, having the virtues as low working pressure, simple operation, less maintenance fee and good discontinuous running performance.
2. It adopts the nitrogen-water pre-cooling system with back cooler and regulated packing, needing much less water in the system.-It equips inter-lock device to avoid water into purifier.


Product Tags:

industrial oxygen gas plant

      

oxygen cylinder filling plant

      
Buy cheap Air Separation Oxygen Gas Plant , 380v 50hz High Purity Liquid Nitrogen Generator product

Air Separation Oxygen Gas Plant , 380v 50hz High Purity Liquid Nitrogen Generator Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Hangzhou Union Industrial Gas-Equipment Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)